| 48mm x 96mm size |
|
|
|
| CB400 Temperature Controller |

A catalog download is here.
CB_05E.pdf (227KB)
(CB series)
Specification files are in Adobe's Acrobat PDF file (version 4.0)
format. Acrobat Reader is required. |
| Input |
Thermocouple, RTD, DC voltage, DC current
* For DC current input, connect a 250W resister (sold separately) to the input terminals. |
| Sampling time |
0.5 sec. |
| Measuring accuracy |
Thermocouple
±(0.3% of reading + 1 digit) or ±2°C (4°F) whichever
is larger
RTD
±(0.3% of reading + 1 digit) or ±0.8°C (1.6°F) whichever
is larger
DC voltage and DC current
±(0.3% of span + 1 digit) |
| Out of an accuracy guarantee range |
Thermocouple R, S, B : 0 to 399°C |
| Control method |
PID control (with autotuning and self-tuning function)
* ON/OFF, P, PI and PD control are also selectable.
Heat/cool PID control (with autotuning) |
| Control output type |
Relay contact output
Voltage pulse output
DC current output : 4 to 20mA
Triac trigger output
Triac output |
| Communications |
RS-485 |
| External Dimensions |
48 x 96 x 100mm (W x H x D) |
| Standard function |
RUN/STOP switching |
| Optional function |
Alarm function : Up to 2 points (Temperature alarm, Heater break alarm,
Loop break alarm)
Dustproof and waterproof protection : IP65 |
|
| Go to "Quick Reference Guide" Index Page. |
|
| Go to Page Top |
|
| CB403 Temperature Controller |

A catalog download is here.
CB3_03E.pdf (191KB)
(CB3 series)
Specification files are in Adobe's Acrobat PDF file (version 4.0)
format. Acrobat Reader is required. |
| Input |
Thermocouple, RTD, DC voltage, DC current
* For DC current input, connect a 250W resister (sold separately) to the input terminals. |
| Sampling time |
0.5 sec. |
| Measuring accuracy |
Thermocouple
±(0.3% of reading + 1 digit) or ±2°C (4°F) whichever
is larger
RTD
±(0.3% of reading + 1 digit) or ±0.8°C (1.6°F) whichever
is larger
DC voltage and DC current
±(0.3% of span + 1 digit) |
| Out of an accuracy guarantee range |
Thermocouple R, S, B : 0 to 399°C |
| Control method |
PID control (with autotuning and self-tuning function)
* ON/OFF, P, PI and PD control are also selectable. |
| Control output type |
Relay contact output
Voltage pulse output
DC current output : 4 to 20mA
Triac trigger output
Triac output |
| Communications |
Not supplied |
| External Dimensions |
48 x 96 x 100mm (W x H x D) |
| Standard function |
RUN/STOP switching |
| Optional function |
Alarm function : Up to 2 points (Temperature alarm, Heater break alarm,
Loop break alarm)
Auxiliary output
Analog output
Contact input (DI)
Dustproof and waterproof protection : IP65 |
|
| Go to "Quick Reference Guide" Index Page. |
|
| Go to Page Top |
|
| REX-D400 Temperature Controller |

A catalog download is here.
D_01E.pdf (79.6KB)
(D series)
Specification files are in Adobe's Acrobat PDF file (version 4.0)
format. Acrobat Reader is required. |
| Input |
Universal input
Thermocouple, RTD, DC voltage, DC current
* For DC current input, connect a 250W resister (sold separately) to the input terminals. |
| Sampling time |
0.5 sec |
| Measuring accuracy |
±(0.3% of spsn + 1 digit) |
| Out of an accuracy guarantee range |
Thermocouple B : Less than 400°C |
| Cold junction temperature compensation error |
Within ±1.5°C (between 0 and 50°C) |
| Control method |
PID control (with autotuning and self-tuning function)
* ON/OFF, P, PI and PD control are also selectable.
Heat/cool PID control (with autotuning and self-tuning function) |
| Control output type |
Universal output (OUT1)
Relay contact output
Voltage pulse output
DC current output
DC voltage output |
| Communications |
RS-485
RS-422A |
| External Dimensions |
48 x 96 x 100mm (W x H x D) |
| Standard function |
Alarm function : Up to 2 points (Temperature alarm, Loop break alarm) |
| Optional function |
Heater break alarm (Single-phase, Three-phase)
Contact input
Analog output |
|
| Go to "Quick Reference Guide" Index Page. |
|
| Go to Page Top |
|
| REX-F400 Process / Temperature Controller |

A catalog download is here.
F_01E.pdf (137KB)
(F series)
Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required. |
| Input |
Thermocouple, RTD, DC voltage, DC current |
| Sampling time |
0.25 sec. |
| Measuring accuracy |
±(0.1% of spsn + 1 digit) |
| Out of an accuracy guarantee range |
Thermocouple B : Between 0 and 400°C |
| Cold junction temperature compensation error |
Within ±1.0°C (between 0 and 50°C)
Accuracy is not guarantee less than input value -100°C. |
| Control method |
ON/OFF control
Brilliant PID control (PI control is selectable.)
(with enhanced autotuning)
Heat/cool brilliant PID control
(with enhanced autotuning)
Position proportioning control |
| Control output type |
Relay contact output
Voltage pulse output
DC current output
DC voltage output |
| Communications |
RS-232C
RS-422A
RS-485 |
| External Dimensions |
48 x 96 x 100mm (W x H x D) |
| Standard function |
| Memory Area : |
8 areas (REX-F700/900) |
|
2 areas (REX-F400) |
| *REX-F400 of 8 areas type if Z-163 is specified. |
|
| Optional function |
Alarm function : Up to 2 points (Temperature alarm, Heater break alarm,
FAIL alarm)
Remote set value function
External contact intput : 1 point (Memory area or Mode change) |
|
| Go to "Quick Reference Guide" Index Page. |
|
| Go to Page Top |
|
| FB400 Process / Temperature Controller |

A catalog download is here.
FB_01E.pdf (871KB)
(FB series)
Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required. |
| Input |
Thermocouple, RTD, DC voltage, DC current |
| Sampling time |
0.1 sec.
0.05 sec. / 0.25 sec. is selectable. |
| Measuring accuracy |
Thermocouple : K, J, T, E, PLII
Less than -100°C : ±1.0°C
-100 to 500°C : ±0.5°C
More than 500°C : ±(0.1% of reading + 1 digit)
Thermocouple : N, S, R, W5Re/W26Re
Less than -100°C : ±2.0°C
-100 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)
Thermocouple : B
Less than 400°C : ±70.0°C
400 to 1000°C : ±(1.4°C + 1 digit)
More than 1000°C : ±(0.1% of reading + 1 digit)
RTD
Less than 200°C : ±0.2°C
More than 200°C : ±(0.1% of reading + 1 digit)
DC voltage and DC current
±(0.1% of span) |
| Cold junction temperature compensation error |
±1.0°C (between 5 to 40°C)
With in ±1.5°C
(between -10 to +5°C , between 40 to 50°C) |
| Control method |
Brilliant II PID control
(with autotuning and startup tuning)
Brilliant II PID control Heat/Cool type
(with autotuning)
Position proportioning control l without feedback resistance (with autotuning) |
| Control output type |
Relay contact output
Voltage pulse output
DC current output
DC voltage output
SSR (Triac) output
Open collector output (Sink type) |
| Communications |
Communication 1
RS-232C
RS-422A
RS-485
* MODBUS
Communication 2 (Inter-controller communication)
RS-485 |
| External Dimensions |
48 x 96 x 60mm (W x H x D) |
| Standard function |
Memory area : 8 areas
Digital input : 3 points (Mode selection)
Remote setpoint input
Waterproof/Dustproof : NEMA4X, IP66
(Waterproof/Dustproof protection only effective from the front in panel
mounted installation.) |
| Optional function |
Ivent (alarm) output : Max. 4 points
Digital input : 4 points (Memory area selection + Area set)
Heater break alarm
Analog retransmission output : 1 point
Position resistance input
Power feed forward function |
|
| Go to "Quick Reference Guide" Index Page. |
|
| Go to Page Top |
|
| HA400 Process / Temperature Controller |

A catalog download is here.
HA_01E.pdf(533KB)
(HA series)
Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required. |
| Input |
Thermocouple, RTD, DC voltage, DC current
* Number of inputs : 2 points |
| Sampling time |
0.025 sec. |
| Measuring accuracy |
Thermocouple : K, J, T, E, PLII
Less than -100°C : ±1.0°C
-100 to 500°C : ±0.5°C
More than 500°C : ±(0.1% of reading + 1 digit)
Thermocouple : N, S, R, W5Re/W26Re
Less than -100°C : ±2.0°C
-100 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)
Thermocouple : B
Less than 400°C : ±70.0°C
400 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)
RTD
Less than 200°C : ±0.2°C
More than 200°C : ±(0.1% of reading + 1 digit)
DC voltage and DC current
±(0.1% of span + 1 digit) |
| Cold junction temperature compensation error |
±1.0°C (at 23°C ± 2°C)
±1.5°C (between 0 to 50°C) |
| Control method |
Brilliant PID control (with enhanced autotuning)
Position proportioning control |
| Control output type |
Relay contact output
Voltage pulse output
DC current output
DC voltage output |
| Communications |
Number of communications : 2 points
RS-232C
RS-422A
RS-485
* MODBUS, DeviceNet, Profibus supported. |
| External Dimensions |
48 x 96 x 100mm (W x H x D) |
| Standard function |
Memory area : 16 areas
Cascade control (only 2 channel type) |
| Optional function |
Ivent (alarm) output : Max. 4 points
Ivent input : 7 points
Remote set value function
Heater break alarm
Analog retransmission output : 3 points
Position feedback resistance input
(Position proportioning control)
Power feed forward function
Waterproof/Dustproof : IP65 |
|
| Go to "Quick Reference Guide" Index Page. |
|
| Go to Page Top |
|
| REX-P48 Ramp/Sork Temperature Controller |

A catalog download is here.
P4896_01E.pdf (75.8KB)
(REX-P48/96)
Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required. |
| Storage program pattern |
Max. 2 patterns
8 segments per pattern
(Max. 16 segments when linking 2 patterns of 8 segments each.) |
| Input |
Thermocouple, RTD |
| Sampling time |
0.5 sec. |
| Measuring accuracy |
±(0.3% of spsn + 1 digit) |
| Out of an accuracy guarantee range |
Thermocouple B : Between 0 and 400°C |
| Cold junction temperature compensation error |
±1.5°C (between 0 to 50°C) |
| Control method |
PID control ( with autotuning )
* ON/OFF, P, PI and PD control are also selectable.
Heat/cool PID control ( with autotuning ) |
| Control output type |
Relay contact output
Voltage pulse output
DC current output |
| Communications |
Not supplied |
| External Dimensions |
48 x 96 x 100mm (W x H x D) |
| Standard function |
Programmable ramp/sork control |
| Optional function |
Level PID control (4 level)
Alarm function : Max. 2 points (Temprature alarm)
Pattern end output : 1 point
Time signal output : 1 point
External contact input : 4 points
(RESET, RUN, HOLD, STEP)
Retransmission output : 1 point |
|
| Go to "Quick Reference Guide" Index Page. |
|
| Go to Page Top |
 |
 |
RKC INSTRUMENT INC. |
|
|
|