| 1-channel Type Temperature Controller with Built-in SSR SB1Series |
Main
| SSR and controller integrated into a compact temperature control box. | |||||||||||
|
|||||||||||
| Can be installed in a small space or onto a pipe. | |
![]() |
Specifications
| Number of input | 1 point |
| Input | a) Therocouple :K, J(JIS/IEC) Range : 0 to 800°C, 0 to 999°F b) RTD : Pt100(JIS/IEC) Range : 0 to 400°C, 0 to 800°F *1/0.1°C(°F) display can be selectable on only communication data. * Universal Input. |
| Measuring accuracy | Thermocouple input 0°C or more, Less than 500°C : ±(1.5°C [2.7°F] + 1digit) 500°C or more : ±(0.3% of Reading + 1digit) RTD input 0°C or more, Less than 200℃ : ±(0.6°C [1.1°F] + 1digit) 200°C or more : ±(0.3% of Reading + 1digit) |
| Cold junction temperature compensation error |
±1°C [1.8°F] (23°C ± 2°C [73°F ±
3.6°F]) ±2°C [3.6°F] ( -10 to +60°C [14 to 140°F]) |
| Sampling time | 0.25 sec |
| Control method | PID control (With autotuning) *P, PI, PD, ON/OFF control selectable |
| Control output | Triac outout (control output) Output method : AC output (Zero-cross method) Allowable load current : 7A (Ambient temperature 40°C or less) ![]() Load voltage : 100 to 240V AC (Same as the power supply voltage) Minimum load current : 50mA ON voltage : 1.5V or less (at maximum load current) Load power shutoff function Internal load power (L side of the power) is turned off by the internal relay at instrument error (FAIL). 0 : Relay for Load power shutoff opens at FAIL (Restores when FAIL is resolved.) 1 : Relay for Load power shutoff opens at FAIL or LBA (FAIL state or LBA state remains.) 2 : Relay for Load power shutoff opens at FAIL or LBA (Returns to the normal state when FAIL state or LBA state recovers.) Peak current suppression function When a group of controllers (up to 4 units) is connected by SB link, use the Peak current suppression function by setting Output limiter high to prevent all outputs from turning ON at the same time. |
| Event (Alarm) function | Number of events : Up to 2 points Event action : Deviation high, Deviation low, Deviation high/low, Band Process high, Process low, SV high, SV low Control loop break alarm (LBA), Monitor during RUN, FAIL Output of the communication monitoring result Event delay timer : 0 to 600 seconds Additional function : Interlock function, Hold action |
| Digital Output (DO) (Optional) |
Number of output : 1 point Output method : Relay contact output (Digital Output) Contact type : 1a contact Contact rating (Resistive load) : 250V AC 1A, 30V DC 0.5A Electrical life : 150,000 times or more (Rated load) Mechanical life : 20 million times or more (Switching : 360 times/min [no-load]) |
| Digital input (DI) (Optional) *Communication cannot be used at the same time. |
Number of input : 1 point Imput method : Dry contact input: Open state : 500kW or more Close state : 10W or less Contact current : 3.3mA or less Voltage at open : Approx. 5V DC Capture judgment time : Approx. 0.25 seconds Function : One of the following functions is selectable : ·Set value 1(SV1) and Set value 2(SV2) select ·RUN/STOP transfer ·AUTO/MAN transfer ·Interlock release |
| Communication (Optional) *Digital input (DI) cannot be used at the same time. |
1) Host Communication Interface : Based on RS-485, EIA standard Protocol : RKC communication protocol (ANSI X3.28-1976 subcategories 2.5 A4) MODBUS-RTU Communication speed : 2400bps, 4800bps, 9600bps, 19200bps Maximum connections : 31 controllers (Address setting range 1 to 99) *SB link function cannot be used for Host Communication function. 2) Inter-controller Communication (SB link) *To use Peak current suppression function, controllers must be connected by SB link function. (Master controller : 1, Slave controller : 3) Interface : Based on RS-485, EIA standard Protocol : MODBUS-RTU Communication speed : 19200bps Maximum connections : Up to 4 controllers *Host communication cannot be used for SB link function. |
| Loader communication (Standard) |
Protocol : RKC standard (ANSI X3.28 subcategory 2.5 A4) Communication speed : 9600 bps Maximum connections : 1 point (Only COM-K) Connection method : COM-K loader cable (W-BV-01-1500) *Power supply from COM-K is available for only internal setting change. Control and host communication are suspended. For this reason, display indicate "---". |
| Supply voltage | 100 to 240V AC (Rating) 90 to 264V AC [Including power supply voltage variation], 50/60Hz |
| Maximum allowable curent of the power supply part | 15A |
| Power saving mode | If no key operation is conducted for the duration being set at Power saving
mode setting, the instrument will be in the Power saving mode by turning
OFF the display (7 segments LED). *Power saving mode switching does not affect the state of the lamp displays. |
| Power consumption | When a load is disconnected 4.0VA max. (at 100V AC), Rush current : 5.6A or less 6.7VA max. (at 240V AC), Rush current :13.3A or less When a load is disconnected in power saving made 3.0VA max. (at 100V AC) 5.2VA max. (at 240V AC) When a load is connected [Ambient temperature : 40°C] 705VA max. (When connecting a load equivalent to 7A at 100V AC), Rudh current 5.6A or less 1690VA max. (When connecting a load equivalent to 7A at 240V AC), Rudh current 13.3A or less |
| Allowable ambient temperature | -10 to 60°C |
| Allowable ambient humidity |
5 to95%RH (Absolute humidity : MAX.W.C29g/m3 dry air at 101.3kPa) |
| Weight | Approx. 130g (Instrument only) |
| Safety standards | UL : UL61010-1 cUL : CAN/CSA-C22.2 No.61010-1 |
| CE marking | LVD : EN61010-1 (OVERVOLTAGE CATECORYⅡ, POLLUTION DEGREE 2) EMC : EN61326-1 |
Dimensions
| Units : mm | |
| Panel mounting type | |
![]() |
|
| DIN rail mounting type | |
![]() |
|
![]() |
|
| Space required between SB1 Allow 30mm or more between the instruments for proper heat dissipation when mounting two or more SB1 controllers in parallel. When mounting the instruments vertically, allow 200mm or more to have space for wiring to or from the connectors installed on the top and the bottom of the SB1. |
|
| Pipe hanging type | |
![]() |
|
![]() |
|
| Pipe wrapping type | |
![]() |
|
![]() |
|
Model Code


Features
| Loader Communication Port | |
| Data can be viewed on site by using the display and operation keys or controlled
remotely via loader communication port. The SB1 has a display, setting keys and loader communication port on the front panel. |
|
![]() |
|
|
|
|
| Power-saving by SB Link | |
| Peak current suppression (SB Link) | |
| When SB1 controllers are divided into groups (max. 4 pcs per group) with
the output limiter, the controllers in the same group will not turn on
simultaneously. Saves energy by limiting the control output around the normal load factor. * SB Link cannot be used simultaneously with a host communication. |
|
![]() |
|
|
|
|
| Safety design | |
| < Load Power Shutoff Function + Fuse > | |
| This function disconnects internal load power with an internal relay. A fuse is incorporated inside the SB1 to protect the instrument from a load short-circuit. |
|
![]() |
|