Specifications

Input
a) Temperature input group
Thermocouple : K, J, E, T, R, S, B, N (JIS/IEC), PLII (NBS), W5Re/W26Re (ASTM)
RTD : Pt100 (JIS/IEC), JPt100 (JIS) · 3-wire system
b) Voltage/Current input group
Voltage input (Input impedance : Approx. 1MW)
0 to 1V DC, 0 to 5V DC, 1 to 5V DC, 0 to 10V DC
Current input (Input impedance : 250W)
4 to 20mA DC, 0 to 20mA DC
* For current input, connect is a 250W shunt resistor to the input terminals. Model code : KD100-55
* Inputs is selectable within each group.
Sampling time 0.25 sec
Measuring accuracy
Input Type Range Accuracy
K, J, T, E *1 Lower than -100°C(-148°F) ±(2.0°C[3.6°F] + 1digit)
-100 to 500°C(-148 to 932°F) ±(1.0°C[1.8°F] + 1digit)
500°C(932°F) or higher ±(0.2% of Reading + 1digit)
N, R, S, PLII *2
W5Re/W26Re
Lower than 0°C(-32°F) ±(4.0°C[7.2°F] + 1digit)
0 to 1000°C(32 to 1832°F) ±(2.0°C[3.6°F] + 1digit)
1000°C(1832°F) or higher ±(0.2% of Reading + 1digit)
B Lower than 400°C(752°F) ±(70°C[126°F] + 1digit)
400 to 1000°C(752 to 1832°F) ±(2°C[3.6°F] + 1digit)
1000°C(1832°F) or higher ±(0.2% of Reading + 1digit)
Pt100, JPt100 Lower than 200°C(752°F) ±(0.4°C[0.7°F] + 1digit)
200°C(392°F) or higher ±(0.2% of Reading + 1digit)
Voltage/Current -span to +span ±(0.2% of span + 1digit)
*1: Accuracy is not guaranteed for less than -100°C(-148°F)
*2: Accuracy is not guaranteed for less than 400°C(752°F) for input type R, S, B and W5Re/W26Re.
Influence of ambient temperature a) Temperature input : ±0.06°C/°C [at 5 to 40°C]
b) Voltage/Current input group : ±0.06% of span/°C [at 5 to 40°C]
Close horizontal mounting error ±2°C(3.6°F) [Less than -100°C(-146°F) input :±3.5°C(6.3°F)]
Control method
a) PID control with autotuning
P, PI, PD, ON/OFF control selectable
Direct action/Reverse action is selectable
b) Heat/Cool type PID control with autotuning
Control output Relay contact output, Form a contact, 250V AC 3A (Resistive load)
Voltage pulse output, 0/12V DC
Current output 4 to 20mA DC, 0 to 20mA DC
Voltage output, 0 to 5V DC, 1 to 5V DC, 0 to 10V DC
SSR (Triac) output Rated current : 0.5A
Open collector output (Sink type)
Communication
(Optional)
RS-485 (ANSI X3.28 sub-category 2.5A4[RKC standard], MODBUS-RTU)
Standard function PV bias
Digital filter
Ramp-to-setpoinst
SV step function : Number of SV : 4 points (Default : 1 points)
Timer function
Loader communication (Communication converter COM-K and software WinUCI for RB series and a Windows XP PC are necessary)
Easy Fine tuning with 6-level of control response adjustment
Optional function Event (Alarm) function : Up to 4 poinsts
Control loop break alarm (LBA)
Heater break alarm (HBA)
Analog retransmission output
Digital input : 2points

Dimensions

* If you specified the waterproof and dustproof structure, four mounting brackets are included with the RB900 as accessories.
* Case rubber packing (optional) [Waterproof/dustproof]
(Unit : mm)
Temperature controller RB900 External Dimensions and Panel cutput
Temperature controller RB700 External Dimensions and Panel cutput
Temperature controller RB500 External Dimensions and Panel cutput
Temperature controller RB400 External Dimensions and Panel cutput
Temperature controller RB100 External Dimensions and Panel cutput

< Close horizontal mounting > Up to 6 units
Close horizontal mounting
Waterproof/dustproof is not available for close horizontal mounting.

Model codes

Temperature controller RB series Model and Suffix Code
*1
*2
*3
When control method is selected for PID control (Code : F, D), output 2 is available for analog retransmissin output.
On the RB100, the event 3 output function can be specified for output 2.
The number of DO points is limited in some combinations of OUT1 and OUT2 (control output) types.

Maximum number of digital outputs (DO) by combinations of output (OUT1 and OUT2)
Maximum number of digital outputs (DO) by combinations of output (OUT1 and OUT2)
Yellow mark : Represents selection of digital outputs DO3 and DO4 are not available.
*1 When the instrument has two digital outputs (DO1 and DO2) and no OUT2 output, "V" type output (load: 40mA) can be specified for OUT1.

Input range code

Inputs is selectable within each group.

Temperature Input Group (Field-programmable)

Temperature controller Input range code

DC Current, Voltage Group (Field-programmable)

Temperature controller Input range code (DC current DC voltage)

Output code

Output 1 Code Table

Temperature controller RB series Output 1 code table

Output 2 Code Table

Temperature controller RB series Output 2 code table

Quick start code

Quick start code tells the factory to ship with each parameter preset to the values detailed as specified by the customer.
Quick start code is not necessarily specified when ordering, unless the preset is requested.
These parameters are software selectable items and can be re-programmed in the field via the manual.
Temperature controller RB series Quick start code
Blue line
New! Communication Software Download
WinUCI-A : Communication Monitor Tool
WinUCI-B for RB series : Communication Setup Tool for RB series
Blue line
Store up to 4 Set Values
Set value changeover is also possible by digital input.
* SV step function : Number of SV : 4 points (Default : 1 points)

SV changeover using digital input
Indication example of four setting value An illustration of the SV reshuffling that used the digital input of the temperature controller RB series

Simple program control using a timer function / setting change proportion limiter
The simple program control illustration that used timer function / setting change rate limiter with the temperature controller RB series in question
Blue line
Blue Mark Temperature controller RB series Top page About a good point of the temperature controller RB series
Red Mark
Panel space saving : 60mm depth Eco Mark
Red Mark Easy maintenance
Red Mark Easy-to-read with large 11-segment LCD display
Red Mark Numerous inputs and outputs (Optional)
Red Mark Calculates optimum PID values to stabilize control faster than ever
Red Mark Sampling 0.25sec
Red Mark Easy Fine tuning with 6-level of control response adjustment
Red Mark
Startup tuning Eco Mark
Red Mark Easy parameter setup via USB loader port (Loader communication)
Blue line
Corporate Profile What's New! Press Release Application Information Products
Home Page
Exhibition Job Opportunities Link Site Map
Blue line
Back RKC INSTRUMENT INC. ©2008 Numerous inputs and outputs (Optional)