| REX-F9000 Specifications |
| Input | |||||||||
| Number of Inputs | 1 or 2 points | ||||||||
| Input | RTD : Pt100 (JIS/IEC), JPt100 (JIS)
|
||||||||
| Input Range | 0.000 to 50.000°C | ||||||||
| Sampling Time | 0.1 sec | ||||||||
| PV Bias | -19.999 to 19.999°C | ||||||||
| Digital Filter | 0.1 to 100.0 sec (No filter when 0.0 is set) | ||||||||
| Performance | |
| Setting Accuracy | a) Temperature : ±0.05°C b) Other setting : Within ±0.1% of setting range |
| Measuring Accuracy | ±0.05°C ( Ambient temperature 23°C ±5°C ) |
| Insulation Resistance | More than 20MW (500V DC) between measured and ground terminals. More than 20MW (500V DC) between power and ground terminals. |
| Dielectric Strength | 1000V AC for one minute between measured and ground terminals. 1500V AC for one minute between power and ground terminals. |
| Control | |||||||||||||
| Control Method | Brilliant PID control with autotuning
|
||||||||||||
| Major Setting Range |
|
||||||||||||
| Control Output |
|
||||||||||||
| Alarms | |||||||||||
| Temperature Alarm |
|
||||||||||
| Alarm Output | Relay output, Form A contact 250V AC 1A (resistive load) Energized or de-energized output |
||||||||||
| Communications | |||||||||
| Communication Method | RS-485 (2-wire) | ||||||||
| Communication Speed | 1200, 2400, 4800, 9600, 19200 BPS | ||||||||
| Bit Format |
|
||||||||
| Communication Code | ASCII (JIS) 7-bit code | ||||||||
| Maximum Connection | 31 (Address can be set from 0 to 99.) | ||||||||
| Contact Input | |||||
| Number of Inputs | 1 point | ||||
| Type | RUN/STOP | ||||
| Input Rating | Non-voltage contact input
|
||||
| Analog Output (Optional) | |
| Number of Outputs | 1 point / channel |
| Output Types | a) Measured value (PV) b) Deviation (DV) c) Set value (SV) d) Manipulated output value (MV) |
| Output Scaling | High limit and Low limit are available. |
| Output Resolution | 13 bits or more |
| Output Accuracy | 0.1% of span |
| Output Ripple | 0.1% of span (When resistive load) |
| NO | Output Signal | Output Impedance | Allowable Load Resistance |
| 4 | 0 - 5 V | Less than 0.1W | More than 1kW |
| 6 | 1 - 5 V | Less than 0.1W | More than 1kW |
| 7 | 0 - 20mA | Less than 5MW | Less than 600W |
| 8 | 4 - 20mA | Less than 5MW | Less than 600W |
| General Specifications | |||||||
| Supply Voltage |
|
||||||
| Power Consumption | Less than 13VA for standard AC type (at 100V AC) Less than 19VA for standard AC type (at 240V AC) Less than 11VA for 24V AC type Less than 340mA for 24V DC type |
||||||
| Power Failure Effect | Not affected by power failure shorter than 20msec, otherwise reset to the initial state. | ||||||
| FAIL Output |
|
||||||
| Operating Environments | 0 to 50°C [32 to 122°F] , 45 to 85% RH | ||||||
| Memory Backup | Backed up by non-volatile memory. Number of writing : Approx. 100,000 times |
||||||
| Net Weight | Approx. 530g | ||||||
| External Dimensions | 96 x 96 x 100mm (W x H x D) | ||||||
| Compliance with Standards | |
| CE Mark UL Recognized CSA Certified |